Two-stage counter-rotating axial local ventilation fans VMEVV-7, VMEVV-8, VMEVV-12, VMEVV-14 with explosion-proof removable motor correspond to the requiremens of TU3146-014-72370116-2011. Designed for ventilation of dead-end coal and ore mine workings, including mine workings with gas and dust hazard, at air density up to 1,3 kg/m3, temperature from 253К to 308К, dust content up to 50 mg/m3 and relative humidity up to 95% (at a temperature of 298К).
Explosion-proof electric motors
First stage impeller
housing
Second stage impeller
Fan skids for ground mounting
Outlet nozzle
Protection bar on the fan inlet
VMEVV fan design
The fan consists of a stage impeller, housing with integrated knife edges, skids, integrated removable motor with a special terminal box supplied with the motor, nozzle, enclosing structure, manifold, and noise mufflers.
— The electric motors are installed in the boring housing and secured by six radial edges and four tie rods.
— Impellers, each with 10 and 8 leaf blades welded to the wheel rim, are mounted on the motor shaft with feather key and end washer.
— The fan is connected to the pipe column by means of a nozzle on which the rubberized pipes are secured with a clamp.
— The fan housing is equipped with arrows indicating the direction of air flow and the direction of the wheel rotation.
— The current from the mains is brought by cable type KOGESH through the terminal boxes.
— For ease of transportation and installation, the fan is mounted on skids and equipped with brackets on the housing to hang it from the mine roof.
Nominal impeller diameter, MM;700;700;700;800;1200;1200;1400;140
Nominal feed, m³/s;7;9;11;13,5;20;34 ;23;36
Nominal total pressure, Pa;6000;6400;6000;8000;4900;5000;6000;6400
Maximum total efficiency factor;0,84;0,84;0,85;0,85;0,84;0,85;0,84;0,84
Electric drive power, kW;37х2;45х2;55х2;90х2;75х2;160х2;90х2;160х2
Rotation speed, min-1;3000;3000;3000;3000;1500;1500;1500;1500
Length, mm;2010;2010;2010;2200;2700;2700;3200;3200
Width, mm;930;930;930;1100;1500;1500;1800;1800
height, mm;1200;1200;1200;1400;1650;1700;1800;1850
Fan unit weight, kg, not exceeding;1450;1500;1570;1800;2800;3500;3500;4000
Feeding within the working area (min, max);...
AERODYNAMIC CHARACTERISTICS
WE'LL MANUFACTURE A PRODUCT WITH CHARACTERISTICS YOU NEED
Each product we manufacture at AO AMZ VENTPROM is adapted to customer needs and operating characteristics